18
-24-
Operating Principle:
Master can select to monitor any one or more remotes via
master switch box.
To talk to remote(s), master closes desired selector switch,
presses talk switch, and speaks into the speaker/microphone.
Master releases talk switch to listen.
Selected remote(s) talk to master “hands-free” without having
to press remote talk switch.
Remotes cannot talk to other remotes.
Remotes not selected by master cannot talk hands-free and
must press talk switch to initiate call to master.
When initiating a call to master, remote must specify its
location for master to respond.
NOTES:
1. Speaker/Microphone
2. Off/On/Speaker Volume Control
3. Talk/Listen Switch
4. Master Selector Switch (customer supplied)
5. Double-Pole (OFF-ON) Toggle Selector Switch
Power
Master
Remotes
120V 50/60Hz AD-27C-1 AD-27D-M49
POWER CONNECTIONS:
BLK HOT 120/240V Models
WHT Neutral 120/240V Models
GRN Earth Ground 120/240V Models
290A4074
REMOTE "B"
MASTER
SEE POWER
CONNECTIONS
MASTER SELECTOR SWITCH BOX
TO REMOTE RB
*
REMOTE "A"
1
4
2
BLK
WHT
GRN
TO OTHER REMOTES
1
3
2
BLK
WHT
GRN
*
*
BLK
WHT
GRN
*
BLK
RED
GRN
WHT
BLK
RED
GRN
WHT
BLK
RED
GRN
WHT
BLK
RED
RC
RB
RA
GRN
WHT
5
3
1
2
3
Vista de pagina 24